Designed to safely connect solar panels, charge controllers, inverters and other components in photovoltaic systems.
CopperTin coating
Red and black, 4 sq mm. Every strand is copper with a tin coating.
The cable for the DC side of your solar system, from panels to the charge controller or inverter. Tinned copper conductor, a UV-resistant ZHFR PVC sheath, and a 1.5 kV DC rating.
Tinned copperThe tin coating helps protect the copper from corrosion outdoors.
UV-resistant PVC, ZHFRZHFR means zero halogen flame retardant. Made for daily sunlight.
Red and blackRed for positive and black for negative, so polarity is easy to see.
1.5 kV DC ratingSuitable for solar DC strings up to 1.5 kV.
| Conductor | Insulation and sheath | Colours | Voltage rating | Sizesq mm |
|---|---|---|---|---|
| Tinned copper | UV-resistant PVC, ZHFR | Red and black | 1.5 kV DC | 4 |
Copper cores in a round sheath. Core colours shown are for illustration.
The cables for the AC side of your solar system, from the inverter to your distribution board and loads. Copper cores, in 2 core and 4 core, from 2.5 to 25 sq mm. It is the same copper round flexible cable as in our Industrial range.
Copper coresBright-annealed 99.97% pure bare copper for low conductor resistance, PVC insulated and sheathed.
2 core and 4 core2 core for single phase runs, 4 core for three phase runs.
FlexibleEasy to bend, route and pull through conduit and tight corners at the inverter and distribution board.
Heat resistantHigh oxygen and temperature index compounds restrict the spread of fire, and the sheath resists abrasion.
| Sizesq mm | 2 core | 4 core |
|---|---|---|
| 2.5 | - | |
| 4.0 | ||
| 6.0 | ||
| 10.0 | - | |
| 16.0 | - | |
| 25.0 | - |
Tap a part of the system to see what its cable has to do.
Sunlight becomes direct current here. The cable that leaves the panels lives outdoors all year, so it has to shrug off sun, rain and heat.
Solar cables are built to withstand harsh outdoor conditions while ensuring efficient power transmission.
Hours of direct sunlight, every day, on the cable jacket.
Rain, dew and damp air around connectors and conduit.
Roof and rooftop-level temperatures on a hot day.
Pulling, bending, clamping and abrasion during and after install.
Longer runs and thinner copper lose more voltage. Set your run and see which size keeps the loss in check.
Voltage drop = 2 × length × current × 0.0225 ÷ size (copper, warm conductor). Indicative only: also check the cable's current rating and have a qualified installer confirm the design.